Abstract:Based on a practical discharge test for CAWS600-R(T) automatic weather station,according to analyze the battery discharge characteristic curve,this paper describes a relationship between the battery discharge voltage and the capacity.Taking the operating voltage change time as site power consumption criterion under different current conditions,the discrimination methods of battery power loss in CAWS600-R(T) station are formed.
姜明, 党岳, 李文博, 崔明, 史静. 区域自动气象站蓄电池亏电判别方法研究——以CAWS600-R(T)型站点为例[J]. 气象水文海洋仪器, 2018, 35(3): 25-30.
Jiang Ming, Dang Yue, Li Wenbo, Cui Ming, Shi Jing. Discrimination methods of battery power loss in regional automatic weather station—Taking CAWS600-R(T) station as an example. Meteorological Hydrological and Marine Instrument, 2018, 35(3): 25-30.
SPONSOR.IEEE recommended practice for maintenance,testing,and replacement of valve-regulated lead-acid (VRLA) batteries for stationary applications[J].IEEE,2014:1-44.