Fault analysis on two state switch of CINRAD/SA radar receiver |
Wu Qiao, Zhu Yongbing, Dong Genming |
Shaoguan Meteorological Bureau of Guangdong, Shaoguan 512026 |
|
|
Abstract A noise temperature alarm of Shaoguan CINRAD/SA weather radar occurred at 2012-03-05T03:53.When the deviation values of the CW and RFD calibration increase, the SYSCAL value also increases and linear channel gain calibration constant appears abnormal.According to analyze the faults by steps, the reason that caused the faults is the loose connection of two state switch.Then, its solutions are put forward in time.
|
Received: 27 January 2014
|
|
|
|
|
[1] |
何建新等.气象雷达原理与系统[M].成都:电子科技大学出版社, 2010.
|
[2] |
北京敏视达有限公司.中国新一代多普勒天气雷达 CINRAD WSR-98D 用户手册(下)接收机手册[M].北京:北京敏视达有限公司, 2001.
|
|
|
|