Exploration for low temperature fault of DZZ5 automatic weather station |
Tan Kai1, Song Yi2, He Wenchang1 |
1.Bazhong Meteorological Bureau,Bazhong 636600; 2.Zhengzhi Town Government of Bazhong,Bazhong 635600 |
|
|
Abstract A low temperature fault of DZZ5 automatic weather station is discussed in detail in this paper.Trying different methods to figure out the fault,eventually it found that it is caused by the system power supply.The fault is eliminated after the power circuit was improved,providing references to deal with similar faults of automatic weather stations in the future.
|
Received: 18 November 2016
|
|
|
|
|
[1] |
华云升达.DZZ5型自动气象站用户手册 [M].北京:华云升达(北京)气象科技有限责任公司,2014.
|
[2] |
宋树礼,汤玲.PWD20型能见度仪的构造、原理和日常维护[J].现代农业科技,2010(2):305.
|
[3] |
华云尚通.HY3000新型站业务软件使用说明书[M].北京:北京华云尚通科技有限公司,2014.
|
[4] |
郭海涛.自动气象站温湿度传感器工作原理及维护[J].山东气象,2005,25(4):51-52.
|
[5] |
Vaisala Oyj.Vaisala能见度传感器操作手册[M].Finland:Vaisala,2011.
|
[6] |
丁圣,王欣.新型自动气象站故障检测方法[J].气象水文海洋仪器,2014,31(2):91-95.
|
[7] |
陈水云,缪集群.DZZ1-2型自动气象站的日常维护与故障处理[J].气象水文海洋仪器,2011,28(4):122-125.
|
[8] |
李红英,唐洪君.DZZ5型自动气象站温湿度传感器故障判断[J].新疆农垦科技,2015(07):73-74.
|
[9] |
黄玉学,张磊,王晨,等.新型自动气象站传感器测试技术及故障处理[J].气象水文海洋仪器,2014,31(4):105-109.
|
|
|
|