A process for integrated faults of new automatic weather station |
Xu Jianping1, Zang Haiguang2, Zhao Chengcheng1 |
1.Weifang Meteorological Bureau,Weifang 261000; 2.Changle Meteorological Bureau,Changle 262400 |
|
|
Abstract This paper introduces the signal transmission modes and wiring diagrams of new automatic weather station.Aiming at the integrated faults caused by lightning strike in Changle automatic weather station,the faults are quickly found and repaired according to the diagrams.Meanwhile,the methods for reducing lightning loss of automatic weather station are discussed,which can provide references for station operating personnel to troubleshoot and maintain the faults.
|
Received: 06 November 2018
|
|
|
|
|
[1] |
仇健,梁伟宜,陈惜茂,等.自动气象站连续遭雷击的原因分析及解决办法[J].广东气象,2015,37(02):69-71.
|
[2] |
中国气象局气象探测中心.新型自动气象站实用手册[M].北京:气象出版社,2016.
|
[3] |
黄思源,刘钧.新型自动气象站观测业务技术[M].北京:气象出版社,2014.
|
[4] |
中国气象局气象探测中心.台站地面综合观测业务软件(ISOS)用户操作手册[M].北京:气象出版社,2014.
|
[5] |
吴明江,牛萍.自动气象站雷电防护分析与探讨[J].气象水文海洋仪器,2010,27(02):99-102.
|
[6] |
蒙召桂,谢华桂,吴其仁.一次雷击造成自动站采集器故障的分析处理[J].气象研究与应用,2013,34(S1):194.
|
|
|
|