Application and Implementation of the PPI Protocol in WTTVS Monitoring and Management System |
YAO Yi-long1, YE Song2, WANG Jing-dong1, GUO Jun2, MA Xiang-hui2 |
1. Nanjing University of Aeronautics & Astronautics, Nanjing 210016 2. Institute of Meteorology and Oceanography, PLA University of Science and Technology, Nanjing 211101 |
|
|
Abstract First, It makes a brief analysis of the PPI communication protocol that packaged by C# language. Then, Combining with the needs that WTTVS monitoring and management system has to read /write PLC internal data storage area, to achieve rapid changes in data-intensive sampling, data storage area V of the PLC is divided into current and historical storage block, the sampling data was temporarily stored in corresponding storage blocks using PLC timer interrupt, PC read and show the data in current storage block real-time, The data in historical storage block was read and batched into the database after the end of system running, achieving intensive sampling data monitoring. Experiment shows that the system works normally and stably. It has achieved the design requirements.
|
|
|
|
|
|
[1] |
孙书静.PLC和PC实时通讯方法的研究[J].电气传动自动化,2012(34):51-53.
|
[2] |
曾碧华.基于西门子PLC的继电器控制系统改进设计与应用[D].浙江:浙江工业大学,2011.
|
[3] |
庄家森,焦小澄.基于PPI通讯协议的监控模块的设计与实现[J].嵌入式技术,2007,30(16):34-40.
|
[4] |
西门子公司.SIMATIC S7-200可编程程序控制器系统手册[M].北京:西门子中国有限公司,2000.
|
[5] |
邓丽霞,刘利云.S7-200系列PLC与PC机通讯问题的探讨[J].工业技术,2011(04):96-97.
|
[6] |
卢志俊,袁可.PPI协议的监控研究[D].重庆,西南大学.2008.
|
[7] |
西门子公司.SIMATIC S7-200 可编程控制器教程[M].北京:西门子中国有限公司,2000.
|
[8] |
龙永辉,孙中生.SIMATIC PPI协议分析[J].工业控制计算机,2005(18):11-12.
|
[9] |
郝金红.Siemens PPI协议分析. PLC解密网: www.plcjiemi.com
|
[10] |
许光彬,王清灵.西门子PPI协议混合类型多单元报文协议剖析[J].机械工程与自动化,2009 (2):40-43.
|
[11] |
蔡锦达,倪建辉,郭瑞等.PPI 协议与西门子 S7- 200 PLC的通讯[J].工业控制计算机,2006(19):13-14.
|
[12] |
Jesse Liberty..Programming C# 4th Edition[M].北京:电子工业出版社,2007.
|
[13] |
何新彪,莫以为,李俚.PC机与PLC通信延迟研究[J].机械与电子,2009(9):15-17.
|
[14] |
孟伟民,王蓓,刘玉清.PLC控制系统中快速变化数据的采集方法[J].仪器仪表用户,2006(3):59-60.
|
|
|
|