Fault analysis on high voltage of 714CDNweather radar related in the flyback charging |
Wang Gang |
Northeast Regional Air Traffic Management Bureau of China Civil Aviation,Shenyang 110043 |
|
|
Abstract According to the characteristics of high voltage section of 714CDN weather radar transmitter,possible reasons for the formation of the IGBT over current fault,empowerment over current fault and feedback over current fault etc that are related to the flyback charging has been analyzed,which can provide a help to analyze and exclude this type of high voltage failure in practical work.
|
Received: 04 January 2013
|
|
|
|
|
[1] |
七八四厂.714CDN C波段机场多普勒天气雷达使用及维护说明书[M].成都:七八四厂,2006.
|
[2] |
七八四厂.714CDN C波段机场多普勒天气雷达技术说明书[M].成都:七八四厂,2006.
|
[3] |
七八四厂.714CDN C波段机场多普勒天气雷达发射机使用说明书[M].成都:七八四厂,2006.
|
[4] |
郑新,李文辉,潘厚忠.雷达发射机技术[M].北京:电子工业出版社,2006.
|
[5] |
魏智.发射机高压脉冲调制器的设计与实践[M].北京:电子工业出版社,2009.
|
[6] |
七八四厂.714CDN C波段机场多普勒天气雷达电原理图册(IGBT 驱动器电原理图JL2.822.049DL)[M].成都:七八四厂,2006.
|
[7] |
七八四厂.714CDN C波段机场多普勒天气雷达电原理图册(充电控制板电原理图JL3.226.010DL)[M].成都:七八四厂,2006.
|
[8] |
郭程,胡细根,宋登亮.充电控制板的故障判定与检修[J].经营管理者,2009(15):341-342.
|
|
|
|