Solutions on power disturbances of DCS2 weighing gauge |
Li Lin, Chang Chen, Zhang Man, Fan Xuebo, Cui Wei, Liu Jincheng, Chen Lu |
Atmospheric Sounding and Technical Support Center of Beijing Meteorological Service, Beijing 100089 |
|
|
Abstract To insure the accuracy of observation data from weighing gauge, based on DSC2 weighing gauge that is pre-installed on two typical weather stations, this paper introduces the precipitation misinformation that caused by the power disturbance. Then, the suggestions are proposed for this malfunction by means of the disturbance analysis of charge controller. The results show that installing DC manostat into the power supply of DSC2 weighing gauge could be an efficient solution.
|
Received: 17 May 2013
|
|
|
|
|
[1] |
陈传振,李爱华.几种降水测量仪器的讨论分析[J].气象水文海洋仪器,2009,26(1):64-65.
|
[2] |
中国气象局.气象仪器和观测方法指南[M].北京:气象出版社,2005.
|
[3] |
姚作新.新疆阿勒泰国家基准气候站ZQZ-BH型称重式固态降水试验研究[J].气象,2011,37(6):714-719.
|
[4] |
苏正军,郑国光,关立友.人工冰核的核化速率实验[J].气象,2010,36(11):46-49.
|
[5] |
张卉慧,何雪松,王本洪.安徽大别山2008年雨雪冰冻灾害地面降水粒子谱分析[J].气象水文海洋仪器,2011,28(2):31-37.
|
[6] |
中国气象局.降水观测规范—称重式降水传感器(试行)[M].北京:气象出版社,2011.
|
[7] |
中国气象局.2010-2011年冬季固态降水自动化观测试验考核总结报告[R].北京,2012.
|
[8] |
李宏,王崇武.现代电力电子技术基础[M].北京:机械工业出版社,2009.
|
[9] |
李黄.自动气象站实用手册[M].北京:气象出版社,2007.
|
|
|
|