Uncertainty analysis of test results for platinum resistance thermometer |
Huang Bin,Kuang Changwu,Lu Tujin,Cui Xuelin,Jing Gaofei |
Hainan Meteorological Observation Center,Haikou 570203 |
|
|
Abstract The platinum resistance thermometer has become a major tool which measures the temperature data. And it needs to be tested in a certain period. According to research methods and analysis steps in JJF1059.1-2012 Evaluation and Expression of Uncertainty in Measurement,a mathematical model of measurement uncertainty is established. The test results uncertainty of the platinum resistance thermometer has been analyzed systematically. It is not only can master measure performance of the standard device of platinum resistance thermometer,but also can explore the ways to reduce the impact of the error.
|
Received: 09 October 2015
|
|
|
|
|
[1] |
叶德培,原遵东,赵峰. 测量不确定度评定与表示JJFl059.1-2012[M].北京:中国计量出版社,2012.
|
[2] |
温晓清,沙奕卓,雷勇. 气象用二等标准水银温度计检定结果不确定度分析[J].气象科技,2008,36(2):240-243.
|
[3] |
朱乐坤,郑丽春. 自动气象站各要素传感器检定结果的不确定度分析[J].应用气象学报,2006,17(5):639-640.
|
[4] |
李施,支询,邢婉茹. 铂电阻温度传感器测量结果的不确定度分析[J]. 科技风,2013,25(23):11-12.
|
[5] |
郭沈辉,戚晓红,王林虎. 恒温槽的校准及不确定度的评定[J].中国测试技术,2007,33(6) :86-89.
|
[6] |
瞿咏梅. 标准铂电阻温度计在0~30℃范围内的不确定度评定[J].计量学报,2001,22(1):40-45.
|
[7] |
李秋平. WLR-60D温度表检定装置不确定度的评定[J]. 吉林农业,2014,25(12):28-29.
|
[8] |
吴勤. 标准铂电阻温度计测量结果不确定度评定[J]. 计量与测试技术,2013,40(11):57-60.
|
[9] |
钱建良,钟青,李欣. 二等铂电阻温度计标准装置的不确定度评定[J]. 电子世界,2013,34(2):99-101.
|
[10] |
崔馨元,吴勤. 标准水银温度计测量结果不确定度评定[J]. 计量与测试技术,2012,39(7):40-41.
|
[11] |
邓艳琴. 二等标准铂电阻温度计校准结果不确定度评定[J]. 江苏电机工程,2010,29(5) :44-47.
|
[12] |
李瑞坚,蔡小宏. 标准电阻自动检定装置测量值的不确定度评定[J]. 计量与测试技术,2014,41(8):85-87.
|
[13] |
姚爱国,刘玉琴. 温度计量标准检定装置不确定度的评定[J]. 青海气象,2008,52(3):35-36.
|
[14] |
闫军,关卫军,孙向阳,等. 用一等标准铂电阻温度计检定二等标准铂电阻温度计结果分析[J]. 计量与测试技术,2011,38(9):41-42.
|
|
|
|