Bubble elimination for the large-scale evaporation gauge of automatic weather station based on RBD |
Wang Chaoran1,Wen Qiang2,Mei Jianjiao3 |
1.Huangshi Meteorological Bureau of Hubei,Huangshi 435000; 2.Shiyan Meteorological Bureau of Hubei,Shiyan 442000; 3.Lincang Meteorological Bureau of Yunnan,Lincang 677000 |
|
|
Abstract Taking AG2.0 ultrasonic evaporation gauge as an example,this paper analyses the problem of abnormal data during the operation in Huangshi National Basic Weather Station.The causes of the problem are analyzed from the aspects of measurement principle and the constitution of the evaporation gauge.And its solving treatment and idea are given out.The deficiencies of the current processing methods for abnormal evaporation data caused by the bubble are specifically pointed out.Meanwhile,the bubble elimination for the large-scale evaporation gauge based on self-created and more efficient RBD method is also given out.
|
Received: 01 May 2016
|
|
|
|
|
[1] |
胡玉峰.自动气象站原理与测量方法[M].北京:气象出版社,2004.
|
[2] |
邵炜剑.自动气象站数据采集器蒸发通道校准系统设计[D].南京信息工程大学,2014.
|
[3] |
李黄.新型自动气象站实用手册[M].北京:气象出版社,2007.
|
[4] |
吴兴高,冯子秦.防城站自动蒸发取水失败原因分析[J].气象研究与应用,2009,30(S1):80-81.
|
[5] |
中国气象局综合观测司.气象装备技术保障手册[M].北京:气象出版社,2011.
|
[6] |
黄晓云,赵晓利,陈文燕,等.CAWS600-SE自动站蒸发故障排查及日常维护[J].气象水文海洋仪器,2013,30(1):111-113.
|
[7] |
后秀芳,吴俊.WUSH-TV2型蒸发传感器的使用注意事项[J].现代农业科技,2013,20(9):256-257.
|
|
|
|