Failure case analysis of automatic weather observing system by lightning stroke |
Zhou Zuxi |
Hunan Air Traffic Branch Management Bureau of Civil Aviation,Changsha 410137 |
|
|
Abstract This paper describes the importance of automatic weather observing system (AWOS)for flight operation and makes a simply introduction for the composition of Vaisala automatic weather observing system.Aiming at a lightning strike failure suffered in the system,a detailed analysis and fault location are carried out.Then,its failure maintenance is researched and pointed out,especially the maintenance of MILOS520 automatic weather station.The lightning strike failure case has a certain reference to equipment maintenance staff,helping them maintain the system better and ensuring the normal operation of the flight.
|
Received: 23 June 2016
|
|
|
|
|
[1] |
周毅洲.机场气象自动观测系统[J].空中交通管理,1996,2(1):33-35.
|
[2] |
李震.芬兰气象自动观测系统的技术保障及故障分析[J].气象水文海洋仪器,2007,24(4):55-56.
|
[3] |
范秀山.事故致因理论:缺陷塔模型[J].中国安全科学学报,2012,22(2):3-9.
|
[4] |
格林威尔科技发展有限公司.MSAP-EE1500说明书[M].北京:格林威尔科技发展有限公司.
|
[5] |
姚陈果,王琪,吴昊,等.基于故障选相及时域、频域分析的输电线路直击雷识别方法及其应用[J].高电压技术,2014,40(5):1298-1305.
|
[6] |
廖必军,刘少武.气象自动观测系统传输线缆通用避雷器设计[J].浙江气象,2010,31(1):39-41,45.
|
|
|
|