Discussion on the verification regulation for temperature sensor of automatic weather station |
Huang Xiaojing, Zheng Liang, Li Xiaohong, Chen Tao |
Sichuan Meteorological Observation Data Center,Chengdu 610072 |
|
|
Abstract This paper takes a comparison between JJG (Meteorology) 002—2015 Platinum Resistance Temperature Sensor of Automatic Weather Station and JJG (Meteorology) 002—2011 Temperature Sensor of Automatic Weather Station,and summarizes the differences in the two verification regulations among three aspects of metering performance requirements,the general technical requirements and measuring instruments control.Combined with theoretical derivation,test data and practical work experience,the rationality of the two provisions are analyzed.The deficiency of JJG (Meteorology) 002—2015 is discussed and the improvement suggestions are put forward.
|
Received: 08 July 2016
|
|
|
|
|
[1] |
国家气象局气候监测应用管理司.气象仪器与观测方法指南[M].北京:气象出版社,1992.
|
[2] |
中国气象局.地面气象观测规范[M].北京:气象出版社,2003.
|
[3] |
JJG(气象)002-2015自动气象站铂电阻温度传感器[S].北京:中国气象局,2015.
|
[4] |
JJG(气象)002-2011自动气象站温度传感器[S].北京:中国气象局,2011.
|
[5] |
IEC 751-1983 Industrial platinium resistance thermometer sensors[S].日内瓦:国际电工委员会,1983.
|
[6] |
罗淇.自然环境校准自动气象站地温传感器超差成因分析[J].气象,2005,31(11):52-54.
|
[7] |
张翠华,张文煜,郭立平.近50年石家庄地面温度变化特征与气候因子的关系分析[J].气象科技,2013,41(3):558-562.
|
[8] |
任燕,王锡芳,孙嫣,等.温度传感器检定数据统计分析[J].气象科技,2016,44(1):19-22.
|
|
|
|