Maintenance methods and fault analysis of intubation automatic soil moisture meter |
Ding Sheng, Yang Haiping |
Yuanjiang Meteorological Bureau,Yuxi 653300 |
|
|
Abstract With the development of the special construction of agriculture,countryside and farmers,each provincial county meteorological bureau has built several agricultural meteorological observation stations.The soil moisture and water content measured by soil moisture meter are important factors for agriculture meteorological services.Effectively repairing and maintaining soil moisture meter in the local can greatly reduce the data missing time and improve the data availability.This paper introduces the working principle and system composition of intubation automatic soil moisture meter.Combined with common fault phenomena in the working,the troubleshooting methods and maintenance key points are summarized comprehensively.
|
Received: 25 October 2016
|
|
|
|
|
[1] |
中国气象局综合观测司.自动土壤水分观测规范(试行)[M].北京:中国气象局,2010.
|
[2] |
马芳,周宏,杨卫洁.DZN3型自动土壤水分观测站故障分析及维护[J].北京农业,2014(21):211,234.
|
[3] |
陈海波,冶林茂,薛龙琴,等.GStar-Ⅰ(DZN2)型自动土壤水分观测仪的维护方法及常见故障解析[J].气象与环境科学,2011,34(S1):178-181.
|
[4] |
刘彬,郭海涛,涂爱琴,等.DZN1型自动土壤水分观测仪的组成与故障排除方法[J].山东气象,2015,35(2):61-63.
|
[5] |
河南省气象科学研究所.GStar-Ⅰ(DZN2)型自动土壤水分观测仪—维护手册[Z].郑州,2011.
|
[6] |
韩艳君,王阔,韩春贤.GStar-Ⅰ型自动土壤水分观测仪故障处理与维护[J].山东气象,2016,36(3):65-68.
|
[7] |
张朝昌,杜衍君,张斌.DZN1 野外式自动土壤水分观测仪常见故障分析[J].安徽农业科学,2013(15):7025-7027.
|
|
|
|