Analysis for a communication failure of Feixian national basic meteorological observing station |
Yu Furong1, Yu Xuping1, Cao Xingfeng1, Zhao Xiaoguang2, Guo Baoyang1 |
1.Linyi Meteorological Bureau,Linyi 276000; 2.Tianzhen Meteorological Bureau,Tianzhen 038200 |
|
|
Abstract Integrated hardware controller has been installed and put into use in Feixian national basic meteorological observing station since at the end of December,2016.This paper gives a detailed analysis for the troubleshooting processes of a communication failure after the integrated hardware running in Feixian station,and the troubleshooting solution thoughts for communication failures are summarized which can provide references for the relevant technical support personnel.
|
Received: 27 September 2017
|
|
|
|
|
[1] |
李黄.自动气象站实用手册[M].北京:气象出版社,2007.
|
[2] |
江苏省无线电科学研究所有限公司.硬件综合控制器用户手册[Z].2014.
|
|
|
|