Measures and analysis of lightning protection rectification of Leping national station |
Ji Guiping1, Chen Baofa1, Ma Zhongyuan2, Huang Longfei1 |
1. Jingdezhen Meteorological Bureau,Jingdezhen 333000; 2. Jiangxi Institute of Meteorological Sciences,Nanchang 330046 |
|
|
Abstract In order to reduce and avoid lightning accident of Leping observation station,aiming at the hidden danger of lightning protection safety of Leping ground meteorological observation station,according to the layout of instruments and equipment in observation field and relevant lightning protection measures,the rectification ideas are put forward.By replacing 232/485 communication lines with optical fiber communication,cutting off the power supply before the strong lightning,using lithium battery power supply,installing lightning rod,strictly grounding the internal and external network,shielding and installing surge protective device,equipotential connection and other methods for lightning protection transformation,the instruments and equipment in the observation field have been effectively protected in the process of many strong lightning.
|
Received: 26 April 2021
|
|
|
|
|
[1] |
邢忆波,杨春明.凤凰山气象观测站的雷电防护设计[J].现代建筑电气,2016,7(7):45-48.
|
[2] |
谢允,杨足明,向力,等.自动气象站雷击故障诊断与防雷措施探讨[J].气象水文海洋仪器,2019,36(1):102-105.
|
[3] |
宋卫民.汉滨区国家基本气象站雷电防护设计[J].陕西气象,2015,58(6):32-34.
|
[4] |
李进,阮志文.地面气象观测站场室防雷改造[J].气象水文海洋仪器,2013,30(3):70-74.
|
[5] |
黎灿明,罗君俏,黎玉燕,等.气象观测场的雷电防护技术探讨[J].气象研究与应用,2018,39(2):131-134.
|
[6] |
王义琴,王凯峰,刘学春,等.武汉国家基本气象观测站的雷电防护探讨[J].安徽农业科学,2015,43(6):218-219.
|
[7] |
黄雷梁,裕昌姚,登鑫.肇庆国家天气雷达站塔楼综合防雷整改应用[J].气象水文海洋仪器,2020,37(4):66-69.
|
|
|
|