Evaluation for measurement uncertainty of indication error of PTB330 pressure sensor |
Wang Xu, Kong Shiyuan, Zhang Haozhe, Wang Xuesong |
Jilin Meteorological Observation Support Center,Changchun 130062 |
|
|
Abstract By establishing the model,this paper analyzes the uncertainty sources of measurement results for PTB330 pressure sensor,and the uncertainty components of measurement results are evaluated.The combined standard uncertainty and extended uncertainty of indication error measurement are obtained.The ten pressure sensors were selected to evaluate the uncertainty of measurement results at each detection point according to the requirements of the verification regulations of pressure sensors for automatic weather station,so as to provide scientific reference for the verification results of the same type of pressure sensors.
|
Received: 14 November 2019
|
|
|
|
|
[1] |
吴丽娜,韩玉婷,赵汀,等.数字类气压传感器测量不确定度评定[J].气象水文海洋仪器,2018,35(4):9-11.
|
[2] |
李庆忠.不确定度评估方法的六个关键点[J].工程与试验,2008,48(S1):16-18.
|
[3] |
王嵘瑜.数字多用表测量结果的不确定度评定[J].计量与测试技术,2019,46(7):117-118.
|
[4] |
沈淘淘,张文东,崔体运.蒙特卡洛法评定木材测湿仪示值误差的不确定度[J].工业计量,2019,29(4):63-66.
|
[5] |
孙哲,黄清治,逄淑蕾,等.湿度传感器示值误差的测量结果不确定度评定[J].黑龙江科学,2019,10(14):66-67.
|
[6] |
魏运芳,王旭,刘宗尧,等.土壤水分传感器校准结果的不确定度分析[J].科技风,2019,32(20):206.
|
[7] |
王宁.测量不确定度评定中的常见错误解析[J].计量与测试技术,2019,46(6):84-86.
|
[8] |
张爱亮,刘悦,陈启悦.气溶胶光度计质量浓度的校准及不确定度评定[J].上海计量测试,2019,46(3):10-11,15.
|
[9] |
栾松年,高洁,王海龙,等.在线温度变送器(配热电阻)的校准方法研究和不确定度评定[J].中国计量,2019,25(6):115-117.
|
[10] |
吴非洋,胡春泉,郑亮.湿度传感器示值修正值的不确定度分析与评定[J].气象水文海洋仪器,2016,33(4):5-8.
|
[11] |
党选发,牛玉质,宋媛,等.空盒气压表测量结果的不确定度评定[J].气象水文海洋仪器,2010,27(1):83-85.
|
|
|
|