Abstract:As fiber optic cables,fiber jumpers,photoelectric converters and other communication equipment and materials are added to the signal transmission lines of the new automatic weather station with optical fiber transmission,faults will be more difficult to troubleshoot if the communication line is not accessible.Taking a fault caused by a short circuit of the data bus from the new automatic weather station of Lianping national basic meteorological observation station as an example.This paper introduces the phenomenon of its failure,analyses of elimination process and summarizes the experience and methods that should be paid attention in troubleshooting and daily maintenance,which can be used as a reference for technical personnel of the station.
卢帮维, 郑学华, 黄旭辉, 谢俊驹. 新型自动气象站数据总线故障案例分析[J]. 气象水文海洋仪器, 2020, 37(2): 98-100.
Lu Bangwei, Zheng Xuehua, Huang Xuhui, Xie Junju. Analysis on fault cases of data bus for new automatic weather station. Meteorological Hydrological and Marine Instrument, 2020, 37(2): 98-100.