Analysis on fault cases of data bus for new automatic weather station |
Lu Bangwei, Zheng Xuehua, Huang Xuhui, Xie Junju |
Lianping Meteorological Bureau of Guangdong,Lianping 517100 |
|
|
Abstract As fiber optic cables,fiber jumpers,photoelectric converters and other communication equipment and materials are added to the signal transmission lines of the new automatic weather station with optical fiber transmission,faults will be more difficult to troubleshoot if the communication line is not accessible.Taking a fault caused by a short circuit of the data bus from the new automatic weather station of Lianping national basic meteorological observation station as an example.This paper introduces the phenomenon of its failure,analyses of elimination process and summarizes the experience and methods that should be paid attention in troubleshooting and daily maintenance,which can be used as a reference for technical personnel of the station.
|
Received: 13 October 2019
|
|
|
|
|
[1] |
中国气象局气象探测中心.新型自动气象站实用手册[M].北京:气象出版社,2016.
|
[2] |
广东省气象计算机应用开发研究所.DZZ1-2型自动气象站技术手册[M].广州:广东省气象计算机应用开发研究所,2003.
|
[3] |
李黄.自动气象站实用手册[M].北京:气象出版社,2007.
|
[4] |
卢帮维,李茂,何金辉.新型自动气象站一次地温异常排除及分析[J].气象水文海洋仪器,2018,35(2):96-98
|
[5] |
黄杰,仲郭军.新型自动气象站温湿度传感器的维修[J].气象水文海洋仪器,2016,33(4):88-90.
|
[6] |
刘晓英.自动气象站校准仪器期间数据的处理[J].气象水文海洋仪器,2015,32(4):103-105.
|
[7] |
李毅聪,周媛.自动气象站故障维修[J].气象水文海洋仪器,2014,31(4):114-116.
|
[8] |
覃晓玲,黄秀秀,彭昊.一次自动气象站故障排除分析[J].气象水文海洋仪器,2018,35(2):77-79.
|
[9] |
于富荣,于旭平,曹兴锋,等.费县国家基本气象站的一次通信故障解析[J].气象水文海洋仪器,2018,35(2):99-101.
|
[10] |
罗风明,邱劲飚,李伟权,等.区域自动气象站故障排查及典型实例分析[J].广东气象,2008,30(3):51-52,60.
|
[11] |
马英洁,张爱玲,吴冠楠.新型自动气象站提高观测数据质量的方法[J].气象水文海洋仪器,2016,33(2):92-94.
|
[12] |
李源鸿,敖振浪,李建勇,等.广东省地面气象综合探测全网实时监控系统[J].广东气象,2007,29(4):5-7.
|
[13] |
廖铭超.自动站深层地温故障分析及解决办法[J].气象研究与应用,2015,36(2):93-95.
|
|
|
|