Uncertainty analysis of field calibration results for meteorological new evaporation |
Zheng Liang1,2, Huang Xiaojing1, Yang Tao1, Li Xiaohong1 |
1. Sichuan Provincial Meteorological Observation Data Centre,Chengdu 610072; 2. Heavy Rain and Drought-Flood Disaster in Plateau and Basin Key Laboratory of Sichuan Province,Chengdu 610072 |
|
|
Abstract The article analyzes the uncertainty of on-site calibration results of evaporation sensors based on a new meteorological evaporation measurement system.According to the requirements of New Evaporation Filed Calibration Method for Automatic Meteorological Station and JJF1059.1-2012 Evaluation and Expression of Uncertaintv in Measurement,10 repeated tests were conducted on the evaporation calibration points,and the combined sample standard deviation was evaluated for type A uncertainty.Analyze the sources of type B uncertainty and conduct an assessment of type B uncertainty.Finally,the two types of uncertainties are combined to obtain the extended uncertainty.The uncertainty analysis of the calibration results of the new evaporative sensor has good reference value for its credibility evaluation.
|
Received: 15 November 2023
|
|
|
|
|
[1] |
郑亮,黄小静,刘宗庆,等.新型蒸发校准误差修正[J].气象科技,2018,46(4):665-669.
|
[2] |
国家气象计量站.自动气象站蒸发传感器检定规程:JJG(气象)006-2011[S].北京:国家气象计量站,2011.
|
[3] |
中国计量科学研究院.规程测量不确定度评定与表示:JJF1059.1-2012[S].北京:中国计量出版社,2012.
|
[4] |
顾龙芳.计量学基础[M].北京:中国计量出版社,2006.
|
[5] |
张建敏.气象计量测试指南[M].北京:中国计量出版社,2011.
|
[6] |
中国气象科学研究院大气探测技术研究中心.自动气象站技术及使用说明书[R].北京:中国气象科学研究院,2002.
|
[7] |
叶德培.测量不确定度理解与应用[M].北京:中国质检出版社,2013.
|
|
|
|