Research on calibration characteristics of humidity sensor for automatic weather station at different temperature |
Yan Pingjiang,Li Wenbo,Yang Bo |
Tianjin Meteorological Exploration Center,Tianjin 300061 |
|
|
Abstract According to the verification regulation of humidity sensor,eight humidity sensors are set to different test temperatures for verification.The data obtained are carried out the error and standard deviation analysis and makes a statistics for qualified situations.The results show that the difference of the test ambient temperature will affect the error and standard deviation of the sensor.Especially in the low temperature condition,the instrument calibration failure rate increases significantly.In practical work,the verification points under low temperature should be added to identify the humidity sensor with too large errors.
|
Received: 24 November 2016
|
|
|
|
|
[1] |
张文煜,袁九毅,等.大气探测原理及方法[M].北京:气象出版社,2007.
|
[2] |
张建敏,罗昶,吕文华.气象计量测试指南[M].北京:中国质检出版社,2011.
|
[3] |
杨波,李文博,张昆.HMP45D与HMP155A温湿度传感器温度特性对比[J].气象科技,2015,43(3):426-429.
|
[4] |
中国气象局.JJG(气象)003-2011,自动气象站湿度传感器检定规程[Z].北京:中国气象局,2011.
|
[5] |
付锡桂,朱乐坤.HMP45D湿度传感器温度特性测试与分析[J].气象科技,2009,37(5):584-586.
|
[6] |
范巧成,田静,宋韬,等.计量基础知识[M].北京:中国计量出版社,2014.
|
[7] |
朱乐坤,郑丽春.自动气象站各要素检定结果的不确定度分析[J].应用气象学报,2006,17(5):635-642.
|
[8] |
国家质量监督检验检疫总局.JJF1001-2011通用计量术语及定义[Z].北京:中国标准出版社,2012.
|
|
|
|