Daily maintenance and fault analysis of PHS-3E pH meter |
Sun Yali, Tian Shiqin, Liu Fei |
Binzhou Meteorological Bureau,Binzhou 256612 |
|
|
Abstract This paper introduces the working principle and working environment of Leici PHS-3E pH meter in detail,as well as the matters needing attention when measuring.In addition,the daily maintenance,common fault analysis and troubleshooting of the composite electrode of pH meter in the process of use are summarized.The data distortion caused by improper use and maintenance of the observer is avoided,so as to improve the accuracy of the measurement data and ensure the smooth progress of acid rain observation.
|
Received: 05 July 2019
|
|
|
|
|
[1] |
中国气象局.酸雨观测业务规范[M].北京:气象出版社,2005.
|
[2] |
邹斌.酸雨观测仪器的日常使用维护及常见故障处理[J].气象水文海洋仪器,2017,34(4):98-100.
|
[3] |
陈海辉,邹定光,朱建华,等.酸雨仪器的维护[J].广东气象,2010,32(5):63-64.
|
[4] |
王荣,逯莹,刘旭升.酸雨观测仪器原理及常见故障判识[J].黑龙江气象,2012,29(2):29-30.
|
[5] |
张运洲,朱明.提高酸雨观测质量的措施[J].农技服务,2012,29(5):633.
|
[6] |
李青建,罗红,吴良标,等.提高酸雨观测质量样品考核方法的研究[J].气象水文海洋仪器,2019,36(4):16-19.
|
[7] |
陈海辉,朱建华,邹定光,等.酸雨pH计的正确使用及其维护[J].气象水文海洋仪器,2009,26(4):75-77.
|
|
|
|