Uncertainty analysis for verification results of DHC2 humidity sensor |
He Tao1, Wang Yanzhao2 |
1. Chengde Meteorological Bureau,Chengde 067000; 2. Cangzhou Meteorological Bureau,Cangzhou 061000 |
|
|
Abstract In order to improve the accuracy of the data collected by the humidity sensor,this paper analyzes the uncertainty of the verification results of the DHC2 humidity sensor.According to the JJG(Meteorology)003—2011 Humidity Sensor of Automatic Meteorological Station and JJF 1059.1—2012 Evaluation and Expression of Uncertainty in Measurement,the values measured during the verification process are calculated and analyzed,and the analysis and evaluation of class A and class B uncertainties are carried out.Finally,the combined uncertainty and extended uncertainty are calculated.The results provide a reference for the uncertainty evaluation of the verification results of humidity sensors.
|
Received: 13 May 2022
|
|
|
|
|
[1] |
施昌彦.测量不确定度评定与表示指南[M].北京:中国计量出版社,2000.
|
[2] |
崔学林,梁宝龙,黄斌,等.湿度传感器测量不确定度评定[J].电子测量与仪器学报,2015,29(10):1544-1549.
|
[3] |
吴非洋,胡春泉,郑亮.湿度传感器示值修正值的不确定度分析与评定[J].气象水文海洋仪器,2016,33(4):5-8.
|
[4] |
邓卫勤.湿度仪示值误差测量结果的不确定度评定[J].气象水文海洋仪器,2015,32(2):24-26.
|
[5] |
杨波.A类评定的几种方法在不确定度评定中的对比分析[J].计量与测试技术,2015,42(12):44-45.
|
[6] |
朱乐坤,郑丽春.自动气象站各要素传感器检定结果的不确定度分析[J].应用气象学报,2006(5):635-642.
|
[7] |
刘宇,张佳佳,刘文忠,等.铂电阻地温传感器检定不确定度评定[J].气象科技,2016,44(5):728-732.
|
[8] |
曾涛,龚熙,边泽强.自动气象站风速传感器测量不确定度评定[J].电子测量技术,2018,41(15):96-99.
|
[9] |
晏敏,柳鸣,刘希林,等.铂电阻温度传感器检定结果的不确定度评定[J].气象研究与应用,2017,38(1):140-143,155.
|
[10] |
于建清,程绍华,贾伟广,等.温湿度传感器相对湿度示值误差测量结果的不确定度评定[J].海洋技术,2013,32(1):83-86.
|
[11] |
陈平.自动气象站温度观测数据不确定度分析方法研究[J].气象水文海洋仪器,2021,38(4):74-75.
|
[12] |
宋媛,吴丽娜.湿度传感器测量结果的不确定度评定[J].气象水文海洋仪器,2021,38(3):70-72.
|
[13] |
汪玮,张世国,王敏,等.降水现象仪测量结果的不确定度评定方法[J].气象水文海洋仪器,2021,38(2):57-60.
|
[14] |
杨卫洁,王欣,胡梅.湿度表的示值误差不确定度分析与评定[J].气象水文海洋仪器,2020,37(3):56-59.
|
|
|
|