Analysis and processing of a lightning strike fault of DZZ5 new automatic weather station |
Liu Bin1, 2, Li Mingya3, Liu Yi2 |
1.Atmospheric Sounding and Technical Support Center of Shandong Meteorological Bureau,Jinan 250031; 2.Zoucheng Meteorological Bureau,Zoucheng 273500; 3.Jinxiang Meteorological Bureau,Jinxiang 272200 |
|
|
Abstract Aiming at an accident of lightning strike of DZZ5 new automatic weather station,a fault phenomenon is described.Through troubleshooting process,the solutions and processing flow are summarized to solve the similar faults,which can provide references for treating this kind of faults.
|
Received: 30 October 2017
|
|
|
|
|
[1] |
吴明江,牛萍.自动气象站雷电防护分析与探讨[J].气象水文海洋仪器,2010,27(02):99-102.
|
[2] |
蒙召桂,谢华桂,吴其仁.一次雷击造成自动站采集器故障的分析处理[J].气象研究与应用,2013,34(S1):194.
|
[3] |
王晓红,陈蓉,李蕾,等.新型自动站的一次雷击故障判别与应用体会[J].南方农业,2016,10(21):215-216.
|
[4] |
杨金玲,张娟.DZZ5型自动气象站常见故障及日常维护[J].气象水文海洋仪器,2017,34(01):102-104.
|
[5] |
中国气象局气象探测中心.新型自动气象站实用手册[M].北京:气象出版社,2016.
|
[6] |
黄思源,刘钧主.新型自动气象站观测业务技术[M].北京:气象出版社,2014.
|
|
|
|