气象水文海洋仪器
 
  中文 | English    
 
Advanced Search
       Jun. 10, 2025 Home  |  About Journal  |  Editorial Board  |  Instruction  |  Subscriptions  |  Download  |  Contacts Us  |  
Meteorological Hydrological and Marine Instrument  2019, Vol. 36 Issue (3): 109-111    DOI:
Maintenance and Repair Current Issue| Next Issue| Archive| Adv Search |
Treatment methods for a collector fault of DZZ3 automatic weather station
Wei Minging1, Kong Haiyang2, Chen Weishan1, Hao Cuiping1, Liu Chuntao1
1.Qingdao Laoshan Meteorological Bureau of Shandong,Laoshan 266102;
2.Shanghai Meteorological Instrument Limited Company,Shanghai 200120

Download: HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  Aiming at the data error of DZZ3 regional automatic weather station in more than one hour and keeping constant continuously,this paper checks and analyses the power supply system,communication system and main collector,finds out the causes of the fault,and puts forward the methods of eliminating,processing flow and solving measures,as well as the matters need to be attention,which can provide reference for other station operators to deal with such failures.
Key wordsautomatic weather station      fault      troubleshooting     
Received: 13 January 2019     
ZTFLH: P415.1+2  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
Wei Minging
Kong Haiyang
Chen Weishan
Hao Cuiping
Liu Chuntao
Cite this article:   
Wei Minging,Kong Haiyang,Chen Weishan等. Treatment methods for a collector fault of DZZ3 automatic weather station[J]. Meteorological Hydrological and Marine Instrument, 2019, 36(3): 109-111.
URL:  
http://www.qxswhy.com/EN/      OR     http://www.qxswhy.com/EN/Y2019/V36/I3/109
Copyright © 2010 Editorial Office of Meteorological, Hydrological and Marine Instrument
Support by Beijing Magtech Co.ltd support@magtech.com.cn